ECFL 30 CABLE FAULT LOCATOR
FOUR INSTRUMENTS IN ONE
■ Active bridge for accurate location of faults where the level of disturbing voltages are low
■ Passive bridge for location of faults where the level of disturbing voltages are high
■ Graaf fault locator for accurate fault location on totally watersoaked cable
■ Time Domain Reflectometer to find low impedance faults and splits causing cross talk between pairs
ACTIVE BRIDGE
■ DC Fault Location Methods: Murray, 3 Point, Küpfmüller, Repeated Küpfmüller
■ AC Fault Location Methods: Interruption, Repeated Küpfmüller.
■ Resistance difference measurement.
■ Loop resistance & Isolation resistance measurement.
PASSIVE BRIDGE
■ DC Fault Location Methods: Murray, 3 Point, Küpfmüller, Resistance difference
■ AC Fault Location Methods: Küpfmüller, Capacitive Balance
■ Loop resistance & Isolation resistance measurement
GRAAF FAULT LOCATOR
■ The Graaf method is based on end to end synchronic current measurement
■ It provides accurate fault location when the disturbing DC voltage is high
TDR
■ Fault location up to 32 km
■ Comparison of pairs
■ Comparison to stored waveform
■ XTALK point location
REMOTE CONTROL
■ ELC 30 loop closing device to open or close the far end of the tested cable
■ ECFL 30S slave unit to perform synchronic end to end Graaf measurement
AUTOMATIC TEST SEQUENCES
■ Automatic quick test of insulation resistance, capacitance, capacitive balance
■ Automatic quality test providing complete test protocols
DISPLAY
■ 320 x 240 dot graphic LCD display with backlight
■ Selectable English, German or Russian languages
USB PORT and PC PROGRAM
■ USB B device-port for direct PC connection
■ USB A host-port for USB stick (Indirect transfer)
■ Optional PC program for result transfer and parameter set edition
|